Signal from Condition
Signal from Condition enables users to create a new signal from statistical functions applied to a signal or condition when it is within another condition. One signal sample will be calculated per capsule for the new signal.
Using the Signal from Condition Tool
Examples Using Signal from Condition
Calculate Equipment Run Hours per Week
Using the Value Search and other tools create a condition which captures when a piece of equipment is operating. Next, create capsules using the Periodic Condition tool which represent the time ranges you would like to aggregate over. For example, if you want to calculate run hours per day, create a daily condition. If you want to calculate run hours per week, create a weekly condition.
Selections in the Signal from Condition Tool
- Select a Signal or Condition - Equipment running condition 
- Summary statistic - Total Duration 
- Convert time units to - Seconds/Minutes/Hours 
- Select a bounding condition - Time period condition 
- Select where to place the timestamp - Start (preferred selection for time aggregations) 
- Select the interpolation method - Step (preferred selection for time aggregations) 
Calculate Equipment Run Hours per Week

Calculate Equipment Cycles per Week

Calculate Equipment Cycles per Week
Using the Value Search and other tools create a condition which captures when a piece of equipment is operating. Next, create capsules using the Periodic Condition tool which represent the time ranges you would like to aggregate over. For example, if you want to calculate cycles per day, create a daily condition. If you want to calculate cycles per week, create a weekly condition.
Selections in the Signal from Condition Tool
- Select a Signal or Condition - Equipment running condition 
- Summary statistic - Count 
- Select a bounding condition - Time period condition 
- Select where to place the timestamp - Middle (preferred selection for discrete interpolation method) 
- Select the interpolation method - Discrete (creates bar chart view) 
Calculate and Trend Cycle/Batch Duration
Using the Value Search or other tools create a condition which captures when a piece of equipment is operating or when a batch starts and ends.
Selections in the Signal from Condition Tool
- Select a Signal or Condition - Equipment running condition 
- Summary statistic - Total Duration 
- Convert time units to - Seconds/Minutes/Hours 
- Select a bounding condition - Equipment running condition 
- Select where to place the timestamp - Start/Middle/End 
- Select the interpolation method - Step/Linear/Discrete 
Calculate and Trend Cycle/Batch Duration

 
                                    